Container operating pressures are based on your application and the configuration of your solvent dispensing area. Below is a summary of the recommended operating pressure ranges for each container type.
|
4 L Model S
|
18 L Model S
|
52 L ASME Model S
|
52 L Model C
|
52 L non-ASME Model S
|
215 L ASME Model S
|
215 L ASME Model C
|
215 L non-ASME Model S
|
225 L Model C
|
1250 L Model S(1)
|
Operating Pressure
|
0-15 psi
|
0-15 psi
|
0-40 psi
|
0-15 psi
|
0-15 psi
|
0-40 psi
|
0-40 psi
|
0-15 psi
|
0-15 psi
|
0-19 psi
|
Pressure Relief Valve venting pressure
|
50 psi
|
50 psi
|
50 psi
|
50 psi
|
50 psi
|
50 psi
|
50 psi
|
50 psi
|
50 psi
|
25 psi
|
(1) Information provided is for 1250 L containers manufactured after October 1998. 1250 L containers manufactured before October 1998 are not designed to be pressure vessels and should only be pressurized to blanket the solvent with inert gas.